POSITIONING THE GAS CYLINDER

Ensure that the gas cylinder is not placed in contact with the Cooker. The hose should be routed away from the Cooker without touching any hot surfaces. Ensure the cylinder is placed on a firm and level surface and that the hose is neither stretched nor twisted when connected. The cylinder must also be located to give good access to connect and disconnect the regulator, or to turn off in an emergency.

 

Each tap may be identified with the corresponding burner.


The oven is thermostatically controlled. Control knob markings are in degrees Celsius and the control is identified by this symbol:

Note: Spark ignition button is located on control panel.

 

LIGHTING and OPERATIONS

Open Top
1. Ensure gas is turned on.
2. Press and turn knob to full flame position.
3. Light burner using taper or match and continue to hold knob in for a further 20 seconds before release.
4. Burner should remain lit; if burner goes out return to Step 1 and repeat ignition procedure.
5. When burner remains lit, turn knob to required position.

Gas supply pipes may contain air so repeat procedure until burner lights.

To Shut Open Top Burner OFF

Turn knob to OFF position.

 

Oven
1. Ensure gas is turned on.
2. Open oven doors.
3. Turn thermostat knob to maximum setting and push in.  This will establish a flow of gas to oven burner.
4. Continue to press knob in and at the same time, push piezo ignitor button situated on control panel to provide a spark at oven burner. Press at 1 sec intervals for 8 times only.
5. Should burner fail to light, wait 3 minutes then return to Step 2 and repeat ignition procedure.
6. Having established burner flame, maintain pressure on knob for a further 20 seconds before release.
7. Burner should remain lit. Should burner fail to remain lit, wait 3 minutes then return to Step 2 and repeat ignition procedure.
8. When burner remains lit, turn thermostat to required temperature setting.

Gas supply pipes may contain air so repeat procedure until burner lights.

To Shut Oven OFF
To extinguish burner, turn thermostat control knob to
OFF position.

IF EQUIPMENT IS FAULTY, DO NOT REPAIR IT! CONTACT US

HELPLINE

Mon – Fri 8am to 5pm 01209 212794  Out of hours: 07817 837057